Test & Measurement Equipment
Innovative & state-of-the-art gears at your doorstep
Global Manufacturers and Suppliers
We gather the most advanced technologies from around the world to bring cutting-edge solutions to our customers. By sourcing innovative tools and systems from leading global innovators, we ensure our offerings remain at the forefront of industry advancements. This commitment to excellence allows us to meet diverse needs across sectors, providing state-of-the-art products and services that drive progress, enhance efficiency, and deliver unparalleled value.
Lithium Battery Test Solutions:
Electrical Test & Measurement Equipment:
Optics and Photonics Components:
Electric Power Equipment:
Quantum Sensing and Metrology:
Cutting-edge Gears
Featured devices and equipment
Lithium Battery Simulator
Kewell B2000-EP Battery Pack Charge-Discharge Test System:
Power 100-600kW
Voltage 12-1200V
Current 0-1200A
Number of channels 8CH
Response/Switch time 500us/1ms
Voltage and current errors of <0.02%F.S.
Roadmap simulation with an interval of 10ms at an error of <0.02%F.S., supportingdynamic test in line with reference standards such as CLTC, WLTC, NEDC, and FUDS.
Data logging time 1ms
Microwave Signal Generator
Neware CTE-8008-5V500A Simulation Testing System:
Current & Voltage: 5V500A
Total Number of Channels: 8CH
Accuracy: 0.05%FS
Min. Pulse Width: 500ms
Others: Simulation/Pulse Test/Capacity Test/Cycle Life/HPPC
Keysight M9484C VXG Vector Signal Generator:
Cover frequency ranges from 9 kHz to 54 GHz and 110 GHz with a V3080A frequency extender
Generate the most demanding signals with the industry's widest signal bandwidth
Enable multi-antenna test applications such as MIMO and beamforming with precise phase coherence and timing synchronization
Supports MIMO real-time fading for all 3GPP 5G NR base station conformance tests with PathWave Signal Generation software
Covers all 5G NR frequency bands and V- / W-band for satellite communications
Generates complex wideband signals needed for carrier aggregation and digital pre-distortion (DPD) applications
Delivers superior RF performance for accurately characterizing devices under test, such as phase noise, error vector magnitude (EVM), and adjacent channel power ratio (ACPR)
Simplifies MIMO and beamforming test setups with up to 4 synchronized and phase-coherent channels in one instrument and more than 32 channels in multiple instruments
Streamlines complex receiver test scenarios with the world’s first 8-virtual-signal emulation per RF channel
Siglent SSG6000A Series Microwave Analog Signal Generator:
Frequency up to 13.6 GHz/ 20 GHz/ 40 GHz
Level setting range: -130 dBm ~ 24 dBm
Excellent Phase Noise: -135 dBc / Hz @ 1 GHz, 10 kHz offset (typ.)
Very low sub harmonic: < –80 dBc
Level error ≤ 0.7 dB (typ.)
Standard AM/FM/PM modulation
Standard OCXO and step attenuator (0 to 110 dB, 10dB step)
Pulse modulation on/off ration > 80 dBc (typ.) and the rise/fall time < 15 ns (typ.) (option)
Pulse train generator has pulse width of 20 ns ~ 300 s and as many as 2047 different pulses (option)
Web browser remote control on PC and mobile terminals
5 inch TFT capacitive touch screen, mouse and keyboard supported
Standard interface includes USB Host, USB Device (USB TMC), LAN (VXI-11, Socket, Telnet). Optional interface: GPIB
Microwave Network Analyzer
Keysight PNA and PNA-X Series Microwave Network Analyzers:
High source output power of +13 dBm at 1 GHz to +11 dBm at 67 GHz
High dynamic range: 134 dB at 20 GHz at test port
Low trace noise: 0.002 dB rms at 1 kHz bandwidth
Low receiver noise floor
High receiver compression level
Fast measurement speed: 3.6 to 23 psec/point
High stability: < 0.03 dB/°C
Siglent SNA6000A Vector Network Analyzer:
Frequency Range: 100 kHz to 13.5 GHz and 100 kHz to 26.5 GHz
Range of IFBW: 1 Hz to 10 MHz
Dynamic Range: 135 dB
Setting Range of Output Level: -55 dBm to +10 dBm
Standard Bias-Tee connection and pulse hardware
4-port models include standard second source
Jumpers / DRA (Source, Ref and Meas) standard on SNA61xxA models
Narrow-linewidth Tunable Lasers
Toptica Single Mode Diode Lasers DFB Pro:
Single-frequency laser with distributed-feedback diode
Available wavelengths: 633 nm, 760 nm .. 3500 nm
Mode-hop free tuning range: Up to 1400 GHz
Reliable operation even in harsh environments
3 laser heads – wide range of options
Quantum Gravimeter
M Squared Lasers Quantum Gravimeter:
Interferometer Footprint 0.7 m x 0.7 m
Interferometer Time T = 50 ms
Repetition Rate > 0.5 Hz
Precision 1.3×10-7 g
Lasers and Electronics Power Consumption < 500W
Footprint 1 m x 0.7 m
Pump Laser Equinox 18 W
Lasers 2 x SolsTiS
Phase Lock Tunable 6.8 GHz phase lock, with < 11 mrad phase noise
Laser Tuning Rate (Lasers locked) ~1 GHz per ms
MuQuans Absolute Quantum Gravimeter:
Sensitivity: 50 µGal/√Hz at a quiet place
5 µGal in1.5 min
2 µGal in 10 min
1 µGal in 40 min
Measurement cycling frequency: 2 Hz
Long-term stability: < 1 μGal
Repeatability: < 2 μGal
Accuracy: few µGal
Dimensions: Sensor head: h = 70 cm / D = 38 cm
Laser & electronics: 100 x 50 x 70 cm3
Mass Sensor head: 25 kg, control unit: 75 kg
Power consumption: 250 W typical
Quantum Microscope
Qnami's Quantum Microscope - ProteusQ™:
Magnetic sensitivity: Better than 2μT/√ Hz in continuous wave operation mode (CW-ODMR: Continuous Wave – Optically Detected Magnetic Resonance spectroscopy)
Sample Size: Max. 40x50mm², 15mm thickness
5x5x15mm³ motorized approach system for XYZ sample positioning, with positioning resolution < 1μm
Low noise, highly stable sample scanner for ultra-stable long term spectroscopic laser alignment, resolution 1nm
Optical diode laser λ=515±5nm, spectral bandwidth (FWHM) < 1.5nm
Tunable output power 0.1μW-20.0mW at focal point
Digital modulation with 150MHz, 2.5ns rise/fall time
Microwave Control: Full frequency bandwidth: 0.3-4GHz, operating frequency bandwidth: 2.5-3.5GHz with resolution: < 10Hz Maximum power: > 30dBm, with 0.1dB power resolution
Single Photon Detection: Dark counts: < 250Hz with dead time: < 35ns, with a count rate of up to 20Mcts/s
NV Bias Magnet: NV bias magnet mounted on objective (vertical direction: -2.5 to +2.5mT, manually adjustable)